AcuteLas Series SPL-1500/SPL-620/SPL-370/SPL-180

    Model: SPL-1500/SPL-620/SPL-370/SPL-180

    Features

    web

    Applications

    web2

    Specification

    SPL-1500/SPL-620/SPL-370/SPL-180 Type pulsed precise scan technology
    Color SPL-1500: Grey
    SPL-620: Grey
    SPL-370: Grey
    SPL-180: White
    Scanning Range*1 SPL-1500: 0.6 ~ 1500 m
    SPL-620: 0.6 ~ 620 m
    SPL-370: 0.6 ~ 370 m
    SPL-180: 0.6 ~ 180 m
    Scanning Accuracy*2 SPL-1500: 3 mm @ 100 m
    SPL-620: 5 mm @ 100 m
    SPL-370: 5 mm @ 100 m
    SPL-180: 5 mm @ 100 m
    Scan Rate SPL-1500: 2,000,000 pts/sec
    SPL-620: 1,200,000 pts/sec
    SPL-370: 500,000 pts/sec
    SPL-180: 500,000 pts/sec
    Angular Accuracy 0.001°(H./V.)
    Scanning FOV 360° (H.) & 300° (V.)
    Laser Class Class1 eye-safe (in accordance with IEC 60825-1:2014)
    Laser Wavelength 1550 nm, invisible
    Laser Beam Divergence 0.3 mrad (1/e)
    Interface USB 3.0, external power supply, Ethernet
    Data Storage USB 3.2 flash drive 256 GB (as default)
    Imaging Resolution inbuilt (24.6 MP in total, 2 x 12.3 MP)
    Scanning Control on-board 5-inch HDR (720x1280) color touch display or web interface remote control on tablet/smartphone
    Dual-axis Compensator compensating range±15°; compensating accuracy 0.008°
    Sensor integrated, height relative (to a fixed point) to detect
    on board
    integrated, orientation to detect
    integrated tracking GPS(L1)&Beidou(B1)
    Power Supply rechargeable battery (as default); external supply by 19V DC
    Power Consumption 25 W (while scanning)
    Battery Endurance max. 4 h per unit (one unit needed for operation only)
    Operating Temperature -20°C ~ +60°C
    Storage Temperature -35°C ~ +70°C
    Humidity Resistance non-condensing
    Ingress Protection SPL-1500: IP64
    SPL-620: IP54
    SPL-370: IP54
    SPL-180: IP54
    Net Weight 6 kg (without battery); 6.45 kg (with battery)
    Dimension 247x107x202mm

    *1. The measured distance is the test conclusion of the laboratory under 80% reflectivity and is for reference only. *2. The measured accuracy is the test conclusion of the laboratory under 80% reflectivity and is for reference only. Note: all information above is subject to change without any prior notice.

    2545